Bare stranded copper.
Bus drop cable nec.
364 8 in the busway article.
Bus drop cable is made for use in indoor or outdoor applications for connection of stationary or portable equipment to facilitate relocation of equipment.
The 1999 nec now refers only to sec.
Bus drop cable and tray cable are service cords that connect a power supply to a machine or device.
They have two or more insulated conductors and a protective jacket that resists abrasion water sunlight and lubricants.
Bus drop cable is typically used as a branch connection from a ceiling cable while tray cable is primarily used for wiring.
This cable is rated for indoor and outdoor use in wet or dry locations.
Bus drop cable pvc insulation pvc jacket applications.
Ampacities are from table 310.
Bus drop cable 60 c 600 volt ul.
The cable is covered with a gray pvc jacket.
For use as drop cable from overhead bus duct to floor machines.
Easily disconnected and connected when machines are moved.
The 1996 nec allowed one building surface attachment.
It is constructed using sizes 14 awg through 2 awg annealed stranded bare copper.
Spec 70168 bus drop cable industrial grade construction.
They have two or more insulated conductors and a protective jacket that resists abrasion water sunlight and lubricants.
Bus drop cable and tray cable are service cords that connect a power supply to a machine or device.
Allied wire and cable s bus drop cable is designed for both indoor and outdoor use in wet or dry locations for the connection of portable or stationary equipment to facilitate their interchange our particular bus drop cable is constructed with a polyvinylchloride jacket and depending on the awg has a temperature rating of either 60 ºc or 75ºc and a voltage rating of 600 volts.
This cable consists of three bare copper insulated conductors and three bare copper 4.
Acic pcs duo power control signal cable csa view pdf.
Stranded bare copper per astm b 8 2.
Installed quickly without use of conduit for fixed or temporary power.
Pcv standrad color gray other colors available upon request applications and features.
Construction applications standards q a.
Pvc colors black white red 3.
Nec 364 8 as branch wiring from busways.
This comes up in locations where you d like to attach the drop to the wall from a wireway run overhead at a central point.
Royal bus drop view pdf.
Resistant to oil grease acids cutting fluids and mechanical abuse.
60 c 140 f 75 c 167 f 90 c 194 f 60 c 140 f.
Bus drop cable is typically used as a branch connection from a ceiling cable while tray cable is primarily used for wiring.